APPENDICES
Appendix 1 Operation Processing Time
949
A
Basic
instruction
LDE= Single
precision
In conductive status 4.400 20.900 4.400 20.900 4.400 20.900 4.700 10.100
In non-conductive status 4.400 20.900 4.400 20.900 4.400 20.900 4.700 10.100
ANDE= Single
precision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.200 19.600 4.200 19.600 4.200 19.600 4.200 12.500
In non-
conductive
status
4.200 19.600 4.200 19.600 4.200 19.600 4.400 11.900
ORE= Single
precision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.200 17.400 4.200 17.400 4.200 17.400 4.600 10.800
In non-
conductive
status
4.200 17.400 4.200 17.400 4.200 17.400 4.500 9.800
LDE<> Single
precision
In conductive status 4.400 20.900 4.400 20.900 4.400 20.900 4.700 7.700
In non-conductive status 4.400 20.900 4.400 20.900 4.400 20.900 4.600 8.200
ANDE<> Single
precision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.200 19.600 4.200 19.600 4.200 19.600 4.300 14.200
In non-
conductive
status
4.200 19.600 4.200 19.600 4.200 19.600 4.400 14.200
ORE<> Single
precision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.200 17.400 4.200 17.400 4.200 17.400 4.600 6.700
In non-
conductive
status
4.200 17.400 4.200 17.400 4.200 17.400 4.400 6.600
LDE> Single
precision
In conductive status 4.400 20.900 4.400 20.900 4.400 20.900 4.700 13.700
In non-conductive status 4.400 20.900 4.400 20.900 4.400 20.900 4.600 13.700
ANDE> Single
precision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.200 19.600 4.200 19.600 4.200 19.600 4.300 8.100
In non-
conductive
status
4.200 19.600 4.200 19.600 4.200 19.600 4.200 8.100
ORE> Single
precision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.200 17.400 4.200 17.400 4.200 17.400 4.600 8.500
In non-
conductive
status
4.200 17.400 4.200 17.400 4.200 17.400 4.400 8.100
LDE<= Single
precision
In conductive status 4.400 20.900 4.400 20.900 4.400 20.900 4.700 11.100
In non-conductive status 4.400 20.900 4.400 20.900 4.400 20.900 4.700 9.600
ANDE<= Single
precision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.200 19.600 4.200 19.600 4.200 19.600 4.100 7.800
In non-
conductive
status
4.200 19.600 4.200 19.600 4.200 19.600 4.400 8.200
ORE<= Single
pr
ec
ision
When not executed 0.360 0.240 0.180 0.120
When
executed
In conductive
status
4.200 17.400 4.200 17.400 4.200 17.400 4.500 10.300
In non-
conductive
status
4.200 17.400 4.200 17.400 4.200 17.400 4.400 9.800
Category Instruction Condition (device) Processing time (s)
Q00UJCPU Q00UCPU Q01UCPU Q02UCPU
Min. Max. Min. Max. Min. Max. Min. Max.