387
168
Parameter for manufacturer setting. Do not set.
169
170
Watt-hour meter clear
0A 8A 2
171
Operation hour meter clear
0B 8B 2

172
User group registered display/batch clear
0C 8C 2
173
User group registration
0D 8D 2

174
User group clear
0E 8E 2
178
STF terminal function selection
12 92 2
179
STR terminal function selection
13 93 2
180
RL terminal function selection
14 94 2
181
RM terminal function selection
15 95 2
182
RH terminal function selection
16 96 2
183
RT terminal function selection
17 97 2
184
AU terminal function selection
18 98 2
185
JOG terminal function selection
19 99 2
186
CS terminal function selection
1A 9A 2
187
MRS terminal function selection
1B 9B 2
188
STOP terminal function selection
1C 9C 2
189
RES terminal function selection
1D 9D 2
190
RUN terminal function selection
1E 9E 2
191
SU terminal function selection
1F 9F 2
192
IPF terminal function selection
20 A0 2
193
OL terminal function selection
21 A1 2
194
FU terminal function selection
22 A2 2
195
ABC1 terminal function selection
23 A3 2
196
ABC2 terminal function selection
24 A4 2
232
Multi-speed setting (speed 8)
28 A8 2
233
Multi-speed setting (speed 9)
29 A9 2

234
Multi-speed setting (speed 10)
2A AA 2
235
Multi-speed setting (speed 11)
2B AB 2

236
Multi-speed setting (speed 12)
2C AC 2
237
Multi-speed setting (speed 13)
2D AD 2

238
Multi-speed setting (speed 14)
2E AE 2
239
Multi-speed setting (speed 15)
2F AF 2

240
Soft-PWM operation selection
30 B0 2
241
Analog input display unit switchover
31 B1 2

242
Terminal 1 added compensation amount
(terminal 2)
32 B2 2
243
Terminal 1 added compensation amount
(terminal 4)
33 B3 2

244
Cooling fan operation selection
34 B4 2
245
Rated slip
35 B5 2

246
Slip compensation time constant
36 B6 2
247
Constant-power range slip compensation
selection
37 B7 2

250
Stop selection
3A BA 2
251
Output phase loss protection selection
3B BB 2

252
Override bias
3C BC 2
253
Override gain
3D BD 2

255
Life alarm status display
3F BF 2
256
Inrush current limit circuit life display
40 C0 2

257
Control circuit capacitor life display
41 C1 2
258
Main circuit capacitor life display
42 C2 2

259
Main circuit capacitor life measuring
43 C3 2
260
PWM frequency automatic switchover
44 C4 2

261
Power failure stop selection
45 C5 2
Parameter
Name