EasyManuals Logo

Mitsubishi F700 Series User Manual

Mitsubishi F700 Series
408 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
I
CONTENTS
CONTENTS
1 OUTLINE 1
1.1 Product checking and parts identification ........................................................ 2
1.2 Inverter and peripheral devices.......................................................................... 3
1.2.1 Peripheral devices ..................................................................................................................... 4
1.3 Method of removal and reinstallation of the front cover ................................. 5
1.4 Installation of the inverter and enclosure design............................................. 7
1.4.1 Inverter installation environment................................................................................................ 7
1.4.2 Cooling system types for inverter enclosure.............................................................................. 9
1.4.3 Inverter placement..................................................................................................................... 9
2 WIRING 11
2.1 Wiring.................................................................................................................. 12
2.1.1 Terminal connection diagram .................................................................................................. 12
2.1.2 EMC filter................................................................................................................................. 13
2.2 Main circuit terminal specifications................................................................. 14
2.2.1 Specification of main circuit terminal ....................................................................................... 14
2.2.2 Terminal arrangement of the main circuit terminal, power supply and the motor wiring ......... 14
2.2.3 Cables and wiring length ......................................................................................................... 17
2.2.4 When connecting the control circuit and the main circuit separately to the power supply....... 20
2.3 Control circuit specifications ........................................................................... 22
2.3.1 Control circuit terminals ........................................................................................................... 22
2.3.2 Changing the control logic ....................................................................................................... 25
2.3.3 Control circuit terminal layout .................................................................................................. 27
2.3.4 Wiring instructions ................................................................................................................... 28
2.3.5 Mounting the operation panel (FR-DU07) on the enclosure surface ....................................... 29
2.3.6 RS-485 terminal block ............................................................................................................. 30
2.3.7 Communication operation........................................................................................................ 30
2.4 Connection of stand-alone option units.......................................................... 31
2.4.1 Connection of the brake unit (FR-BU2) ................................................................................... 31
2.4.2 Connection of the brake unit (FR-BU/MT-BU5)....................................................................... 33
2.4.3 Connection of the brake unit (BU type) ................................................................................... 35
2.4.4 Connection of the high power factor converter (FR-HC/MT-HC)............................................. 35
2.4.5 Connection of the power regeneration common converter (FR-CV)
(01160 or less)......................................................................................................................... 37
2.4.6 Connection of the power regeneration converter (MT-RC)
(01800 or more)....................................................................................................................... 38
2.4.7 Connection of the power factor improving DC reactor (FR-HEL) ............................................ 38
3 PRECAUTIONS FOR USE OF THE INVERTER 39

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi F700 Series and is the answer not in the manual?

Mitsubishi F700 Series Specifications

General IconGeneral
Humidity95% RH or less (non-condensing)
Control MethodV/F control
Protection FeaturesOvercurrent, overvoltage, undervoltage, overheat, short circuit
Communication OptionsRS-485
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +65°C
AltitudeUp to 1000m above sea level
Overload Capacity150% for 60 seconds
Cooling MethodForced air cooling
Power Range0.75 to 630 kW (1 to 845 hp)
Output Voltage3-phase 200 to 240 VAC, 380 to 500 VAC (matching input voltage)