EasyManua.ls Logo

MLC LC100 - 4.11 P-M-L Modul - Type P

MLC LC100
148 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
117
LC100 Instruction manual
4.11 P-M-L Modul - Type P
4/6 Parameters
11/12 P-M-L Modul
Type P
In the PML modul menu it is possible to set the work of the signalization modules LC100-P, LC100-M or LC100-
L. Sign under the letter means that for that module is activated mode which is explained in the description:
Example shows setting of the cabin signalization module (adress 0) which will display:
Cabin position (A)
Car travel direction (B)
Sound signal for stopping (D)
Sound and light signal for STOP (G)
Adress of P, M or L modul
A 00 Cabin modul A side.
A xx Landing modul A side in xx floor.
B 00 Cabin modul B side.
B xx Landing modul B side in xx floor.
Configuration for cabine and landing calls modules:
A Car position signalization
Displays floor markings defined in G-00 to G-40 parameters.
B Car travelling direction signalization
Displays up and down arrow when elevator is driving
C Next car travel direction signalization
Displays up and down arrow when elevator is driving, and after stopping shows next drive direction
D Sound signal for car stopping (arriving to the floor)
E Sound signal for unlocking the landing doors
F Sound and light signal for cabin overload
G Sound and light signal for STOP
H Sound and light signal for landing door open.
I Sound and light signal for active photocell
J „Out of order“ light signalization
K „Fire program active“signalization
L Disable landing call
M „Landing call button pressed“ sound signal, for modul A-0 „New cabin call“ sound signal
V- speaker volume (1 to 7)

Table of Contents