4.11 P-M-L Modul - Type P
In the PML modul menu it is possible to set the work of the signalization modules LC100-P, LC100-M or LC100-
L. Sign „ “ under the letter means that for that module is activated mode which is explained in the description:
Example shows setting of the cabin signalization module (adress 0) which will display:
Cabin position (A)
Car travel direction (B)
Sound signal for stopping (D)
Sound and light signal for STOP (G)
Adress of P, M or L modul
A – 00 Cabin modul A side.
A – xx Landing modul A side in xx floor.
B – 00 Cabin modul B side.
B – xx Landing modul B side in xx floor.
Configuration for cabine and landing calls modules:
A – Car position signalization
Displays floor markings defined in G-00 to G-40 parameters.
B – Car travelling direction signalization
Displays up and down arrow when elevator is driving
C – Next car travel direction signalization
Displays up and down arrow when elevator is driving, and after stopping shows next drive direction
D – Sound signal for car stopping (arriving to the floor)
E – Sound signal for unlocking the landing doors
F – Sound and light signal for cabin overload
G – Sound and light signal for STOP
H – Sound and light signal for landing door open.
I – Sound and light signal for active photocell
J – „Out of order“ light signalization
K – „Fire program active“signalization
L – Disable landing call
M – „Landing call button pressed“ sound signal, for modul A-0 „New cabin call“ sound signal
V- speaker volume (1 to 7)