LC100 Instruction manual
4.1 General - Type A
4/6 Parameters
1/12 General
Type A
A-1
Number of stops
2-40
Setting the number of floors.
It is possible to set up to 40 floors.
A-2
Number of elevators
1-8
Number of elevators in multiplex.
It is possible to set up to 8 elevators in multiplex.
A-3
Elevator marking
A-H
Elevator marking im multiplex mode.
When elevator is working in multiplex mode it is necessairly to define the
elevator marking. First elevator is „A“, second is „B“ and so on.
In multiplex there can't be two elevators with same marking because the
communication and landing calls processing will not work correctly.
A-4
Evacuation
0-2
Parameter for choosing the type of emergency passanger evacuation.
0 there is no emergency evacuation
1 automatic evacuation of the passangers
2 manual evacuation by pressing the brake open button from the
cabin.
A-5
Configuration LC100
---
Parameter to include the LC100-I, LC100-VFD, LC100-Y, LC100-SR board into
system.
If there exist board connected to CAN bus it needs to be included through A-5
parameter. Including is done by placeing the sign under the board
character.
for software version less than 4.410.00
A-5
Configuration LC100
---
Parameter to include the LC100-I, LC100-VFD, LC100-VFX, LC100-SR,
LC100-SR2 bord into system. If there exist bord connected to CAN bus it needs
to be included through A-5 parameter. Including is done by placeing the sign
under the „board“ character.
In firmware 4.410.00 or newer.