LC100 Instruction manual
INPUT FUNCTIONS TABLE
NO
DYSPLAY ON LC100-D
DESCRIPTION
FI-201
Input function for switching to recall program.
FI-202
Recall pushbutton up input function.
FI-203
Recall pushbutton down input function.
FI-204
Input function for power supply phase loss relay control.
FI-205
Input function for controling the safety circuit control device used for
relevelling and preopening the doors.
FI-206
Input function for elevators with short safety space. After the input is once
activated (input FI-206) elevator is blocked until reset button on the LC100-
D2 is pressed or activation of input FI-327
FI-207
Input function for emergency passanger evacuation. After the input is active
elevator begins evacuation acording to the parameter A-04
FI-208
Input function for motor bimetal sensor. After the input is activated function
motor fan FO-18 is switched on.
FI-209
Input for fan contactor control.
FI-210
Input for fire program 1. After the input is activated elevator goes to fire
program, existing calls are ignored, elevator goes to the station which is
defined in the parameter B-07. After the elevator ends with the fire program it
is blocked until input is switched off.
FI-211
Input for fire program 2. After the input is activated elevator goes to fire
program, existing calls are ignored, elevator goes to the station which is
defined in the parameter B-08. After the elevator ends with the fire program it
is blocked until input is switched off.
FI-212
Input for fire program 3. After the input is activated elevator goes to fire
program, existing calls are ignored, elevator goes to the station which is
defined in the parameter B-09. After the elevator ends with the fire program it
is blocked until input is switched off.
FI-213
Input for fire program 4. After the input is activated elevator goes to fire
program, existing calls are ignored, elevator goes to the station which is
defined in the parameter B-17. After the elevator ends with the fire program it
is blocked until input is switched off.
FI-214
Reset input for LC100-C board.
FI-215
Input for out of order status of the elevator.
FI-216
Input function for time relay 1. Setting the time relay is explained in
parameters type H
FI-217
Input function for time relay 2. Setting the time relay is explained in
parameters type H
FI-218
Input for disableing the landing calls.
FI-219
Input for elevator test mode. After the input is activated elevator is in normal
drive but the landing calls are disabled and shaft light control is disabled.
FI-220
Input for up travel contactor control.
FI-221
Input for down travel contactor control.
FI-222
Input for low speed contactor control.
FI-223
Input for high speed contactor control.