10/05 AWB8230-1541GB
Holding register (word
variable)
177
1116 C023 Reserved rw
1117 C024 Reserved rw
1118 C025 Reserved rw
1119 C026 Relay K1 – signal rw Values a PNU C021
111A C027 Reserved rw
111B C028 Analog output AM,
measured value indication
selection
rw 00: f-Out: Current output frequency
01: I-Out: Current output current
111C C029 Reserved
rw
111D C031 Digital output 11 – logic
rw 00: Normally open contact (NO)
01: Normally closed contact (NC)
111E C032 Digital output 12 – logic rw Values a PNU C031
111F C033 Reserved rw
1120 C034 Reserved rw
1121 C035 Reserved rw
1122 C036 Relay K1 (K11-K12) – logic rw Values a PNU C031
1123 C040 Reserved
rw
1124 C041 Output function – warning
threshold for overload signal
(OL)
rw 0 – 2 x Ie [A] Default, dependent on frequency
inverter’s rated current (Ie)
0.01 [%]
1125 C042 Reserved
rw
1126 C042 Output function – signalling
threshold for frequency
signal FA2 during
acceleration
rw 0 – 400 Hz 0.1 [Hz]
1127 C043 Reserved
rw
1128 C043 Output function – signalling
threshold for frequency
signal FA2 during
deceleration
rw 0 – 400 Hz 0.1 [Hz]
1129 C044 Output function: Signalling
threshold, maximum PID
control deviation
rw 0 – 100 % 0.1 [%]
112A C045 Reserved rw
112B C045 Reserved rw
112C C046 Reserved rw
112D C046 Reserved rw
112E C052 PID controller – switch-off
threshold for second stage
of PID controller
rw 0 – 100 % 0.1 [%]
112F C053 PID controller – switch-on
threshold for second stage
of PID controller
rw 0 – 100 % 0.1 [%]
1130 C055 Reserved rw
1131 C056 Reserved
rw
1132 C057 Reserved
rw
Holding
register
Function
code
Name
Access
rights
Value range Manipulated
variable
hex