Appendix
10/05 AWB8230-1541GB
232
PNU RUN b031
= 10
Name Value range DS page
H003
––
Motor – assigned rating
[kW]/{HP} at rated voltage (U
e
)
0.2; 0.4; 0.55; 0.75; 1.1; 1.5; 2.2; 3.0; 4.0; 5.5; 7.5; 11.0
{0.2; 0.4; 0.75; 1.5; 2.2; 3.7; 5.5; 7.5; 11.0}
Default depends on rated voltage and type rating.
–64
H203
––
Motor – assigned rating
[kW]/{HP} at rated voltage (U
e
)
(second parameter set)
Values a PNU H003 64
H004
––
Motor – number of poles 2, 4, 6, 8 4 64
H204
––
Motor – number of poles
(second parameter set)
Values a PNU H004 4 64
H006 jjMotor – stabilization constant 0 – 255 100 64
H206 jjMotor – stabilization constant
(second parameter set)
Values a PNU F006 100 64