7.1 Error Messages
7-3 ZM2371/ZM2372
7.1.2 Errors at Panel Operation
Main errors due to the panel operation are as listed below.
Specified settings could not be
made due to the restriction by
other settings.
Use within restricted conditions.
Or, change the settings that
restrict others.
DC bias voltage setting was
limited so that it does not exceed
the maximum output voltage
(about 7Vpeak) because
measurement signal level is large.
Reduce the signal level when large
DC bias voltage is required.
Measurement signal level setting
was limited so that it does not
exceed the maximum output
voltage (about 7Vpeak) because
DC bias voltage is output.
Reduce the DC bias voltage setting
or turn off the DC bias output
when large measurement signal is
required.
Contents of settings or correction
value memory are destroyed.