3.2 Display at Power “ON” and Initial Setting
3-5 ZM2371/ZM2372
3.2.2 Displays and Indications at Power ON
Take necessary steps before instrument usage/operation according to “2. PREPARATIONS
BEFORE USE.
When the power switch is turned on, a test pattern is displayed, and then a starting
message including the model name “ZM2371” or ZM2372 and firmware version is
displayed (see below).
Example: Z M 2 3 7 2
V 1 . 0 0 2 0 0 9 / 6 / 1 5 1 6 : 2 7
Version Last adjustment date and time
Also, all lamps light up. During this time, the self diagnosis is conducted. If an error is
found, an error message is displayed.
For details “7.1.1 Errors at Power-On
If a serious error is found, the device will no longer operate with an error message displayed.
When a setting or correction value has been lost, an error message is displayed but the
parameter for which the error occurred is initialized and started. This error message can be
reset by pressing any key.
Initialization contents 3.2.3 Initialization
The settings and correction values at the time when the power was turned off last are
resumed unless the resume memory that saves last settings is normal.