52 B 1050 en-1819
1 Switching pin protection
2 Mechanical switch
Figure 22: Switching pin with separate mechanical switch
The triggering temperature of the switching pin is usually 120 °C. This ensures that the system is shut
down before the temperature for the melting safety device is reached.
The alignment of the mechanical switch must be checked with the aid of the manufacturer's
documentation prior to commissioning.
The switch must be connected to the evaluation electronics by the operator.
As standard, turbo couplings are usually supplied filled with oil.
Pos: 10 3 /Anlei tung en/G etrieb e/3. Mo ntag e, Lager ung , V orb ereit ung, A ufs tell ung/ Ant rie bs kuppl ung _0 6-Za hnkuppl ung [B 1050, B 2050] @ 30\mod_1552982806276_388.docx @ 2511871 @ 4 @ 1
3.22.1.3 Dog coupling
NOTICE! Gear unit damage
Dog couplings require lubrication with grease to ensure wear-free function:
• Dog couplings must be re-greased according to the manufacturer's documentation prior to commissioning.
Pos: 10 4 /Allg emein/ Allg emeing ültig e Mod ule/---------Sei tenumbr uch ko mpakt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1