Industrial gear units – Operating and Assembly Instructions
84 B 1050 en-1819
5x07, 6x07 7x07-10x07 11x07-15x07
Option
Instal-
lation
orien-
tation
207 307 407 507 207 307 407 507 207 307 407 507
Vent M1 1/2 /OT 1/2 /OT 1/2 /OT 1/2 /OT 1/2 /OT 1/2 /OT
M2 16 /OT 16 /OT 16 /OT 16 /OT 16/17 /OT 16/17 /OT
M3 9/10 /OT 9/10 /OT 9/10 /OT 9/10 /OT 9/10 /OT 9/10 /OT
M4 5/6 /OT 5/6 /OT 5/6 /OT
M5 13/14 /OT 13/14 /OT
M6 7/8 /OT 7/8 /OT
Key:
Standard position in housing
Standard only possible in oil tank
--- Special, not possible in standard
If option OT, then always in the oil tank
Optionally in the housing
Table 14: Position of housing options on oil screw holes (standard installation positions)
Pos: 21 2 /Allg emein/ Allg emeing ültig e Mod ule/---------Sei tenumbr uch ko mpakt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1