EV Series Automated Dispensing Systems
44
Testing the System Setup and Calibration
# Click Step
1
ONLY SYSTEMS WITH A TIP DETECTOR:
Click NEEDLE Z DETECT to test the setup.
Click YES/OK when prompted for conrmations.
NOTES:
- When the system performs a Needle Z Detect, it automatically performs a
Needle XY Adjust directly after performing the Needle Z Detect.
- Refer to “How the System Responds to Needle Z Detect or Needle XY
Adjust” on page 44 for a detailed description of the system response to
a Needle Z Detect selection.
2
SYSTEMS WITHOUT A TIP DETECTOR:
Click NEEDLE XY ADJUST to test the setup.
Click YES/OK when prompted for conrmations.
Refer to “How the System Responds to Needle Z Detect or Needle XY
Adjust” on page 44 for a detailed description of the system response to a
Needle XY Adjust selection.
The system is now properly set up and calibrated. Refer to “Programming” on
page 48 to create programs.
How the System Responds to Needle Z Detect or Needle XY Adjust
NOTE: On systems with the optional tip detector, both the Needle XY Adjust and Needle Z Detect buttons are
present. On systems without the optional tip detector, only the Needle XY Adjust button is present.
When you click NEEDLE Z DETECT, the system performs the following actions:
Moves the dispensing tip over the Tip Detector sensor and lowers it until it touches the sensor.
Measures and compares the difference between the last measurement and the current measurement.
Requests conrmation for any change in the tip-to-workpiece offset (Z clearance).
Realigns all points in the currently open program to the new tip-to-workpiece offset (Z clearance).
Automatically performs a Needle XY Adjust sequence (shown below).
When you click NEEDLE XY ADJUST, the system performs the following actions:
Moves the dispensing tip to a preset location on the workpiece.
Dispenses a dot of uid.
Moves the camera over the deposited dot of uid.
Compares the alignment of the dot with the mark image saved in the Mark Library.
Requests conrmation for any change in the camera-to-tip offset (XY offsets).
Realigns all points in the currently open program to the new XY offsets.