Changing the IP address causes the
IPC to boot
192.168.0.99
255.255.255.0
IPC IP-adress
Subnet mask
Operation
4-57
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
IP Address Setup
These settings are needed to communicate with the IPC when using the
Webserver. They must be clearly defined in an EtherNet network.
IPC IP-address: 192.168.0.99
Subnet mask: 255.255.255.0
Fig. 4-71 V21a
Example: Setting IP Addresses in a Network
All Nordson melters are delivered with the same IPC IP address. To be able
to work together in a network, every device, including a PC, must be
assigned its own IP address (Fig. 4-72).
The subnet mask mentioned above allows changes to be made to the last
part (host of melter part) of the IP address.
NOTE: All IP addresses ending with 1 to 254 are possible. IP addresses
ending with 0 or 255 are not permitted.
PC IP address:
192.168.0.98
IPC IP address:
192.168.0.99
Change to IPC
IP address:
192.168.0.100
IPC IP address:
192.168.0.99
IPC IP address:
192.168.0.99
Change to IPC
IP address:
192.168.0.101
Fig. 9-72 IP addresses in a network Example

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson VersaBlue VB Series and is the answer not in the manual?

Nordson VersaBlue VB Series Specifications

General IconGeneral
BrandNordson
ModelVersaBlue VB Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals