172 System configuration
Prompt Response Description
KEY 0 aaa yyyy, for
example,
0 SCR 5001
0 aaa yyyy = Primary UEXT DN, where:
aaa = MCN, MCR, SCN, or SCR
yyyy = primary DN
1 HOT P nn yyyy,
for example,
1 HOT P 6 445010
1 hot p nn yyyy = Target DN, where:
nn = DN length (maximum length is 32)
yyyy = <TSC+ subscribed DN on DAP>
Configuring CLID
Before configuring CLID, create a CPND block.
CLID is configured with LD 95.
Table 23
LD 95: Configure CLID
Prompt Response Description
REQ NEW
TYPE NAME
CUST
n
n = customer number
DN xxxx, for example
5001
DN configured at the DAP and UEXT Key 0 at DN.
NAME aaaaaa, for
example
Nick Johns
Handset user name
Enabling message waiting indication
The following configuration in Customer Data Block must be presented to
enable Message Waiting Indication (MWI) for IP DECT handsets.
Note: Package 175 must be enabled on the Call Server for this feature.
MWI is configured with LD 15.
Table 24
LD 15: Enable message waiting indication
Prompt Response Description
REQ CHG
TYPE IMS IMS_DATA
CUST
n
n = customer number
...
Nortel Communication Server 1000
SIP DECT Fundamentals
NN43120-123 01.07
6 January 2009
Copyright © 2008-2009 Nortel Networks
.

Table of Contents

Other manuals for Nortel CS 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nortel CS 1000 and is the answer not in the manual?

Nortel CS 1000 Specifications

General IconGeneral
BrandNortel
ModelCS 1000
CategoryServer
LanguageEnglish

Related product manuals