EasyManua.ls Logo

Oki B6200 - 1.2 How to Start Up M;C

Oki B6200
679 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 - 2
Chapter 2 Operation of Diagnostic
8. "ON LINE" key
Press the "ON LINE" key holding down the " " and " " keys to start the Diag (C/E) mode.
9. "CANCEL" key
Instructs an interruptible Diag Code to stop. This key is ineffective for any uninterruptible Diag
Code.
10. "POWER SAVE" key
Use this key in special M/C start-up procedures.
1.2 How to Start Up M/C
Five ways of starting up M/C are available depending on an operation when turning on the power
supply.
How to start up M/C and an operation when turning on the power supply are described below.
How to start up M/C
Operation when turning on
power supply
Usage
Normal boot Turn on the power supply without
pressing any key.
Use in a normal way.
Long boot
(with self-diagnosis)
Turn on the power supply while
pressing the "POWER SAVE" and
"FEED / SELECT" keys
simultaneously.
In a normal boot sequence, [Normal
boot diag] is executed to omit the
device (ESS) diagnosis items and
reduce the start-up time. On the other
hand, [Long boot diag] is executed
for more detailed diagnosis of the
device. The diagnosis items and the
differences are as follows:
RAM diagnosis:
Write/Read/Verify test is
executed for the entire area.
Program ROM diagnosis:
The checksum is calculated to
check the ROM and necessary
actions are taken.
Font ROM diagnosis:
The checksum is calculated to
check the ROM and necessary
actions are taken.
NVRAM Clear Boot Turn on the power supply while
pressing the "POWER SAVE" and
" " keys simultaneously.
Initialize the configuration area
(printer setting value, etc.) of NVRAM
(ESS), and start up the system. (Job
Log is not erased.)
NVRAM/Spool Clear Boot Turn on the power supply while
pressing the "POWER SAVE" and
" " keys simultaneously.
If any error occurs when spooling in
HDD and the system does not start
up even though turning OFF/ON the
power supply, erase the spool area in
HDD and start up the system. Then,
initialize the NVRAM (ESS)
configuration area (printer setting
value, etc.) too. (Job Log is not
erased.)
Down Load Turn on the power supply while
pressing the "POWER SAVE" key.
Set to the download mode when
upgrading the firmware version of the
main unit.

Table of Contents

Other manuals for Oki B6200

Related product manuals