Chapter 4 Plug/Jack(P/J) Connector Locations
2. Connector [P (plug) / J (jack)] (24PPM)
2.1 List of P/J (24PPM)
P/J Coordiates Remarks
1 G-104 Connects OPERATION PANEL and HARNESS ASSY PANEL
10 A-111 Connects HARNESS ASSY LVPS and HVPS/MCU
11 D-111 Connects HARNESS ASSY LVPS and HVPS/MCU
13 E-111 Connects HARNESS ASSY ROS and HVPS/MCU
14 E-112 Connects HARNESS ASSY ROS and HVPS/MCU
15 F-112 Connects HARNESS ASSY ANT and HVPS/MCU
16 G-111 Connects HARNESS ASSY ROS and HVPS/MCU
17 G-111 Connects HARNESS ASSY ROS and HVPS/MCU
18 F-112 Connects HARNESS ASSY LVPS and HVPS/MCU
20 H-111 Connects HARNESS ASSY FDR1 and HVPS/MCU
22 I-110 Connects HARNESS ASSY TONER1 and HVPS/MCU
24 J-110 Connects HARNESS ASSY CHUTE and HVPS/MCU
26 I-110 Connects HARNESS ASSY LOW PAPER SNR and HVPS/MCU
27 D-111 Connects HARNESS ASSY LVPS and HVPS/MCU
28 K-110 Connects FFC ASSY ESS and HVPS/MCU
 29 *1
K-108 Connects HARNESS ASSY EXIT SNR1 and HVPS/MCU
 30 *1
K-107 Connects HARNESS ASSY OCT1 and HVPS/MCU
30 K-106 Connects HARNESS ASSY PANEL and ESS
31 C-111 Connects GUIDE ASSY CRU and HVPS/MCU
31 K-107 Connects HARNESS ASSY LVPS and PWBA ESS
32 K-109 Connects FFC ASSY ESS and PWBA ESS
40 X-122 Connects HARNESS ASSY LVPS and LVPS
41 X-123 Connects HARNESS ASSY LVPS and LVPS
42 W-122 Connects HARNESS ASSY LVPS and LVPS
43 X-123 Connects MAIN MOTOR and LVPS
44 X-124 Connects INTERLOCK SW REAR and LVPS
45 X-124 Connects INTERLOCK SW 24V and LVPS
46 X-125 Connects HARNESS ASSY FUSER and LVPS
47 U-127 Connects HARNESS ASSY FUSER and LVPS
48 V-127 Connects HARNESS ASSY 100V and LVPS
101 V-121 Connects LVPS and PWBA EXIT MOTOR
102 U-121 Connects HARNESS ASSY LVPS and PWBA EXIT MOTOR
103 S-121 Connects MOTOR ASSY EXIT and PWBA EXIT MOTOR
131 B-111 Connects ROS ASSY and HARNESS ASSY ROS
140 A-108 Connects ROS ASSY and HARNESS ASSY ROS
141 U-121 Connects HARNESS ASSY ROS and HARNESS ASSY LVPS
142 R-120 Connects HARNESS ASSY LVPS and INTERLOCK SW 5V
144 K-105 Connects INTERLOCK SW and HARNESS ASSY LVPS
150 M-123 Connects PWBA ASSY ANT and HARNESS ASSY ANT
160 A-107 Connects ROS ASSY and HARNESS ASSY ROS
170 A-106 Connects ROS ASSY and HARNESS ASSY ROS
220 R-128 Connects SENSOR TONER and HARNESS ASSY TONER1
221 M-126 Connects HARNESS ASSY TONER1 and HARNESS ASSY TONER2
240 M-124 Connects SENSOR NO PAPER and HARNESS ASSY TRAY1
241 O-127 Connects SENSOR REGI and HARNESS ASSY TRAY1
242 Q-128 Connects CLUTCH ASSY PH and HARNESS ASSY TRAY1