1 - 51
Chapter 1 Troubleshooting
FIP1.44 Face Up Tray Error
Step
Check Yes No
Possible causative parts:
HVPS/MCU (PL12.1.19)
SENSOR FACE UP OPEN (PL10.1.25)
GATE FU (PL10.2.6)
LEVER GATE FU (PL10.2.17)
1
Checking Actuator for operation
Does ACTUATOR FULL STACK in GATE FU move
smoothly, when moving LEVER GATE FU up and down?
With tool
Go to step 2.
Without tool
Go to step3.
Replace GATE
FU.
2
Checking SENSOR FACE UP for operation
Remove EP CARTRIDGE.
Does the number of Sensor/Switch Check increase by
one, every time moving LEVER GATE FU up and down?
Checks by Chapter 2 Diagnostic [Sensor/Switch Check].
Go to step 3.
Go to FIP2.45
SENSOR FACE
UP OPEN.
3
Checking SENSOR FACE UP OPEN for operation
Replac SENSOR FACE UP OPEN.
Does the problem still occur, after replacing SENSOR
FACE UP OPEN?
Replace
HVPS/MCU.
(RRP12.10)
End of work