Chapter 1 Troubleshooting
FIP1.8 Paper Jam/Exit
Step
Check Yes No
Possible causative parts:
FUSER ASSY (PL8.1.20)
HVPS/MCU (PL12.1.19)
HARNESS ASSY FUSER (PL8.1.17)
MOTOR ASSY EXIT (PL10.1.15)
LVPS (PL12.1.5)
ROLL PINCH EXIT (PL10.1.23)
CHUTE LW EXT2 ASSY (PL9.1.2)
500 EXIT ASSY (PL10.1.2)
150 PAPER CASSETTE (PL2.1.50)
250 PAPER CASSETTE (PL3.1.50)
550 PAPER CASSETTE (PL4.1.50)
1
Checking the paper condition
Is the paper crumpled, damaged or damp?
Replace the
paper with a new
and dry one.
Go to step 2.
2
Checking the paper size setup
Does the paper size in use match the size setup by GUIDE
ASSY END or by the driver on the PC?
Go to step 3.
Replace the
paper, or set up
the paper size
correctly.
3 Does Error occur when the power is turned ON? Go to step 4. Go to step 6.
4
Checking the paper in Actuator Exit
Is there any remaining paper in Actuator Exit?
Remove the
paper, and go to
step 5.
Go to step 8.
5 Does Error occur when the power is turned ON? Go to step 8. Go to step 6.
6
Carrying out a test printing
Does Error occur?
Checks by Chapter 2 Diagnostic [TEST PATTERN MODE
MENU].
Go to step 7. End of work
7
Checking ROLL PINCH EXIT
Remove COVER TOP ASSY (PL1.1.7). (RRP1.4)
Is ROLL PINCH EXIT not damaged, and rotating
smoothly?
Does SPRING PINCH EXIT attach?
Turn ROLL EXIT with a finger to check.
Go to step 8.
Replace ROLL
PINCH EXIT.
8
Checking ROLL EXIT (PL9.1.19) for rotation
Remove EP CARTRIDGE.
Close COVER OPEN (PL1.1.2).
Turn the power ON.
Does ROLL EXIT rotate smoothly during warm up?
Go to step 9.
Replace CHUTE
LW EXT2 ASSY.
(RRP9.1)
9
Checking Actuator Exit for operation
Remove EP CARTRIDGE.
Does Actuator Exit move smoothly, when touching
Actuator Exit with a finger inserted from the exit of FUSER
ASSY, and moving it up and down?
With tool
Go to step 10.
Without tool
Go to step 11.
Replace FUSER
ASSY. (RRP8.8)

Table of Contents