2 - 13
Chapter 2 Operation of Diagnostic
DC135 HFSI
Description: Change a current status value (hereinafter referred to as the "current life") and a change
Interval value (hereinafter referred to as "spec life") of a specified consumable item.
• [Clear Life]
Clear a current life value of a changed HFSI component to zero.
• [Change Life]
Change an initial value of a spec life which refers to the time to change the HFSI component.
However, there is no component whose spec life can be changed at this moment.
Even if a current life exceeds a spec life, counting-up continues. However, if a
counted value reached a maximum value, the maximum value is held.
<Clearing a current life value>
Procedure:
1. Enter the Diag (C/E) mode, and select the [Preventive Diag DC122 SDHistory] screen in a lower
level using the " → " key.
2. Select [Preventive Diag DC135 HFSI] in the same hierarchical level using the " ↓ " key.
3. Show the applicable DC item screen [DC135 HFSI Clear Life] using the
" → " key.
4. Show the current life clear screen using the "FEED / SELECT" key again.
• To set the chain-link No., move the cursor using the " ← " or " → " key and change a numerical
value using the " ↑ " or " ↓ " key.
When the cursor is positioned at the left end of the chain-link No., pressing the " ←
" key allows you to return to the [DC135 HFSI Clear LIfe] screen in an upper
hierarchical level.
5. The chain-link No. is fixed by pressing the "FEED / SELECT" key. Then, "*" is marked at the right
end of the changed value.
6. If there is any applicable chain-link No., show the current life using the "FEED / SELECT" key.
7. If there is no applicable chain-link No., the screen below is shown.
8. The current life display screen is changed into the zero clear instruction screen by pressing the "→ "
key.
Clear Life
0
00-000
Clear Life
008-002 NG