1 - 70
Chapter 1 Troubleshooting
FIP2.14 MOTOR ASSY EXIT (PL9.1.11, PL10.1.15)
Step
Check Yes No
Possible causative parts:
MOTOR ASSY EXIT (PL9.1.11, PL10.1.15)
PWBA EXIT MOTOR (PL12.1.4)
HARNESS ASSY LVPS (PL12.1.1)
LVPS (PL12.1.5)
HVPS/MCU (PL12.1.19)
1
Checking MOTOR ASSY EXIT for operation
Not using DIAG tool
Replace MOTOR ASSY EXIT. (RRP9.2)
Is the problem cleared, after replacement?
End of work Go to step 3.
Using DIAG tool
Does the MOTOR ASSY EXIT rotate?
Checks by Chapter 2 Diagnostic:
[Exit Motor, Clockwise Test]
[Exit Motor, Counterclockwise, High Speed Test]
[Exit Motor, Counterclockwise, Low Speed Test]
End of work Go to step2.
2
Checking MOTOR ASSY EXIT
Replace MOTOR ASSY EXIT. (RRP9.2)
Is the problem cleared, after replacement?
End of work. Go to step 3.
3
Checking HARNESS ASSY LVPS for continuity
Disconnect P/J27, P/J10, P/J102 and P/J101 from
HARNESS ASSY LVPS.
Are the following continuous normally?
J27 <=> J102
Go to step 4.
Replace
HARNESS ASSY
LVPS.
4
CheckingMOTOR ASSY EXIT power source voltage
Disconnect P/J101 from PWBA EXIT MOTOR.
Is the voltage across J101-2 <=> J101-1, 24 VDC?
Go to step 5.
Replace LVPS.
(RRP12.3)
5
Checking PWBA EXIT MOTOR
Replace PWBA EXIT MOTOR. (RRP12.2)
Is the problem cleared, after replacement?
End of work
Replace
HVPS/MCU.
(RRP12.10)