Chain Link Fault Items Conditions of detect/Methods of treatment Ref FIP
001 300 Top Cover Open
Detect Top Cover or Top Cover & Rear Cover OpenDefect of SWITCH
I/L ASSY, Confirmation of contact/wiring
FIP1.6
001 301 Rear Cover Open
Detect Rear Cover Open onlyDefect of INTERLOCK S/W REAR,
Confirmation of contact/wiring
FIP1.6
001 302 OCT Cover Open
Detect OCT Cover OpenDefect of SWITCH REAR COVER,
Confirmation of contact/wiring
FIP1.37
(Separate
volume)
001 306 Duplex Cover Open
Detect Duplex Cover OpenDefect of SWITCH DUPLEX, Confirmation
of contact/wiring
FIP1.26
(Separate
volume)
001 398 FAN Motor Fail
One of FAN MAIN or FAN SUB doesn’ t rotate in specified revolutions.
Check Main Fan/Sub Fan and MCU and replace as needed
FIP 1.4
003 346
Scope-FD send error
detected by
Controller(Parity error)
Communication fails is caused because ACK is not received by resend
in twice.Parity error is detected in HARDWARE of IOT side.
If the trouble is not recovered by powering OFF and ON, execute the
following.
- Check the connection of HVPS/MCU connect harness.
- If the trouble is still caused, replace HVPS/MCU PWB.
FIP2.18
003 347
Scope-FD send error
detected by
Controller(Framing error)
Framing error is caused because ACK is not received by resend in
twice.
If the trouble is not recovered by powering OFF and ON, execute the
following.
- Check the connection of HVPS/MCU connect harness.
- If the trouble is still caused, replace HVPS/MCU PWB.
FIP 2.18
003 348
Send error detected by
Controller Detect
incorrect command in
sending ENOSTR
Power OFF and ON -
003 349
Send error detected by
Controller Sending under
runESPIPE
Power OFF and ON -
003 350
Varieties of errors
detected by Controller
EIO
Power OFF and ON -
003 354
Parity error is caused in
receiving a status from
IOT
It is caused when receiving NAK which reporting the communication
fail.
Check the connection of HVPS/MCU connect harness.
If the trouble is still caused, replace HVPS/MCU PWB.
-
003 356
Overrun is caused in
receiving a status from
IOT
It is caused when receiving NAK which reporting the communication
fail.Check the connection of HVPS/MCU connect harness.
If the trouble is still caused, replace HVPS/MCU PWB.
-
003 360
Initialization error
between IOT-ESS
Fail to initialize IOT (MCU).
Check the connection of HVPS/MCU connect harness.
Replace HVPS/MCU PWB.
-
003 362
PAGE-SYNC is caused
before the preparation of
video output is completed.
PageSync becomes active before writing output data until buffer
becomes full when printing.
Replace the harness to connect ESS and IOT.
Replace ESS PWB.
-