2 - 8
Chapter 2 Operation of Diagnostic
1.10 DIAG CODE
DC122 SDHistory
Description: Specify either “Paper Jam” or “Other Faults” category to show the latest 20 items of
history information.
• Register only a jam or fault which requires CE actions (supply, change, repair) in
History.
• The history is cleared automatically when exiting the Diag mode at the
completion of a task.
• The history cannot be cleared by DC301 NVM Init.
• Register also a jam and failure occurred during Diag execution.
<Listing paper jams>
Procedure:
1. Enter the Diag (C/E) mode, and select the [Preventive Diag DC122 SDHistory] screen and then the
[DC122 SDHistory Paper Jam] screen in a lower level using the " → " key.
2. Show the history of a paper jam using the " → " key again.
• The information shown as a history is a chain-link No. and total DV (in the order from left to right
of the upper field), and the date and time of occurrence (in the order from left to right of the lower
field). The time of the internal clock, which is used to record the date and time of occurrence, can
be adjusted in the specification settings.
3. Show the history of the next (previous) paper jam using the " ↑ " or " ↓ " key.
4. Press the "MENU" key to return to the initial screen [Diag. Menu Preventive Diag].
<Listing other faults>
Procedure:
1. Enter the Diag (C/E) mode, and select the [Preventive Diag DC122 SDHistory] screen and then the
[DC122 SDHistory Paper Jam] screen in a lower level using the " → " key.
2. Show the applicable DC item screen [DC122 SDHistory Other Faults] using the " ↓ " key.
3. Show the history of another fault using the " → " key again.
• The information shown as a history is a chain-link No. and total DV (in the order from left to right
of the upper field), and the date and time of occurrence (in the order from left to right of the lower
field). The time of the internal clock, which is used to record the date and time of occurrence, can
be adjusted in the specification settings.
4. Show the history of the next (previous) other fault using the " ↑ " or " ↓ " key.
5. Press the "MENU" key to return to the common menu screen [Diag. Menu Preventive Diag].
008-002 1234567
02/12/24 12:56