2 - 9
Chapter 2 Operation of Diagnostic
DC131 NVM R/W
Description: Reads from and writes to NVM.
Procedure
1. Enter the Diag (C/E) mode, and select [Diag. Menu Adjustment] in the same hierarchical level using
the " " key.
2. Show the applicable DC item screen [Adjustment DC131 NVM R/W] using the " " key.
3. Show the chain-link No. input screen using the " " key again.
To set the chain-link No., move the cursor using the " " or " " key and change a numerical
value using the " " or " " key.
When the cursor is positioned at the left end of the chain-link No., pressing the "
" key allows you to return to the [Adjustment DC131 NVM R/W] screen in an upper
hierarchical level.
4. The chain-link No. is fixed by pressing the "FEED / SELECT" key.
If there is any applicable chain-link No., the current value of NVM and the cursor are shown.
If there is no applicable chain-link No., the NG screen is displayed as shown below. In this case,
press the "FEED / SELECT" key to return to the chain-link No. input screen.
5. To change the current value of NVM, move the cursor using the " " or " " key and change a
numerical value using the " " or " " key.
6. The changed value is rewritten by pressing the "FEED / SELECT" key. When the value is rewritten
properly, "*" is marked at the right end and the key operation becomes available.
When the changed value cannot be rewritten, the [Read Only] screen (Figure-4) is shown for a
read-only NVM or the [Value NG] screen (Figure-5) is shown if the changed value is invalid. In
this case, press the "FEED / SELECT" key to return to the chain-link No. input screen.
DC131 NVM R/W
0
00-000
755-002
0
000000000
755-002
number NG
755-002
Read Only