EasyManua.ls Logo

Oki B6200 - Fip2.44 Motor Assy Exit (Pl10.1.15)

Oki B6200
679 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1 - 77
Chapter 1 Troubleshooting
FIP2.44 MOTOR ASSY EXIT (PL10.1.15)
Step Check Yes No
Possible causative parts:
MOTOR ASSY EXIT (PL10.1.15)
HARNESS ASSY LVPS (PL12.1.1)
PWBA EXIT MOTOR (PL12.1.4)
HVPS/MCU (PL12.1.19)
LVPS (PL12.1.5)
1
Checking MOTOR ASSY EXIT.
Not using DIAG tool:
Replace MOTOR ASSY EXIT. (RRP10.5)
Is the problem cleared?
End of work Go to step 3.
Using DIAG tool:
Does the MOTOR ASSY EXIT rotate?
Checks by Chapter 2 Diagnostic:
[Exit Motor, Clockwise Test]
[Exit Motor, Counterclockwise, High Speed Test]
[Exit Motor, Counterclockwise, Low Speed Test]
End of work Go to step 2.
2
Checking MOTOR ASSY EXIT
Replace MOTOR ASSY EXIT. (RRP10.5)
Is the problem cleared?
End of work Go to step 3.
3
Checking HARNESS ASSY LVPS for continuity
Disconnect P/J27, P/J10, P/J102 and P/J101 of HARNESS
ASSY LVPS.
Are the following continuous normally?
J27 <=> J102
Go to step 4.
Replace
HARNESS ASSY
LVPS.
4
Checking the power to MOTOR ASSY EXIT
Disconnect P/J101 from PWBA EXIT MOTOR.
Is the voltage across J101-2 <=> J101-1, 24 VDC?
Go to step 5.
Replace LVPS.
(RRP12.3)
5
Checking PWBA EXIT MOTOR
Replace PWBA EXIT MOTOR. (RRP12.2)
Is the problem cleared, after replacement?
End of work
Replace
HVPS/MCU.
(RRP12.10)

Table of Contents