2 - 18
Chapter 2 Operation of Diagnostic
DC301 NVM Init.
Description: Initializes an NVM area.
In [NVM Init.], any settings for a billing counter, M/C serial No., market, HFSI,
shutdown history and jam/fail counter are not initialized. Settings for a shutdown
history and jam/fail counter are cleared by selecting the [Exit Diagnostics Complete
Exit] screen when exiting the Diag mode.
In [NVM Init.], only [area:SYS] can be executed. [area:IOT] and [area:ALL] cannot be
executed ("Parameter NG" is shown). Therefore, NVM is initialized by downloading
an output setting value for the MCU NVM initialization through the firmware
upgrade. Two types of output setting values are available as described below:
1. Initialization file
Initializes NVMs, except for the following items specific to the machine.
• Serial No.
• Counter (Billing, HFSI, etc.)
• Shipment adjustment item (Color/Tray Regi., relation, magnification, Loop
amount, etc.)
2. Specified Place (Address) Rewriting File
Rewrites the contents of specified address in NVM, mainly for troubleshooting.
Procedure:
1. Enter the Diag (C/E) mode, and select the [Diag. Menu Adjustment] screen in a lower level using
the " → " key.
2. Select [Adjustment DC131 NVM R/W] in the same hierarchical level using the " ↓ " key.
3. Show the [Adjustment DC301 NVM Init.] screen using the " ↓ " key.
4. Show the initialization setting item screen using the " → " key.
5. Initialize the SYS area using the "FEED / SELECT" key. After initializing, "*" is marked at the right
end of the area display and the key operation becomes available.
6. Show the [NVM Initialized Please exit Diag] screen to prompt you to exit the Diag mode, using the "
← " or "MENU" key.
7. Press the "MENU" key to return to the common menu screen [Diag. Menu Adjustment].
DC301 NVM Init.
SYS