3 – 195
Chapter 3 Removal and Replacement Procedures (RRPs)
Removal
1) Remove the EP CARTRIDGE and Paper Cassettes.
2) Remove the COVER REAR 500/COVER REAR 250 (PL10.2.21/9.1.12). (RRP10.9/9.4)
3) Remove the FUSER ASSY (PL8.1.20). (RRP8.8)
4) Place the printer down on its right side.
Be careful not to scratch the cover, and do not given a shock to the printer from a
top.
5) Disconnect the connector (P/J260) of the HARNESS ASSY LOW 1 (PL7.1.2) from the SENSOR.
6) Release the hooks of the SENSOR, and remove it from the GUIDE TRAY RIGHT (PL7.1.3).
Replacement
1) Install the SENSOR LOE PAPER to the GUIDE TRAY RIGHT (PL7.1.3), and secure it with hooks.
2) Connect the connector (P/J260) of the HARNESS ASSY LOW 1 (PL7.1.2) to the SENSOR.
3) Return the printer to the normal use state.
4) Install the FUSER ASSSY (PL8.1.20). (RRP8.8)
5) Install the COVER REAR 500/COVER REAR 250 (PL10.2.21/9.1.12). (RRP10.9/9.4)
6) Install the EP CARTRIDGE and Paper Cassettes.