Oki Data CONFIDENTIAL
42615101TH Rev.8 235 /
7.5.4 Actions Taken after Forced HDD/Flash Initialization
This section describes actions taken after forced HDD or Flash initialization in the event of
problems in HDDs or Flash.
1) Actions after Forced HDD Initialization
Forced HDD initialization erases the following data. There are no data recovery methods.
• Internal not-yet-printed data
• JobAccount log data (when JobAccount has been activated)
2) Actions after Forced Flash Initialization
Forced Flash initialization erases the following data, causing network inoperability.
• NIC firmware
• Mac addresses
• Web page data
• OEM-oriented demonstration page data (in printers to OEM purchasers)
Using maintenance utility software, Flash must be programmed with the above NIC-firmware, Mac
addresses and Web page data.
Note!
Do not implement it normally.