4-15
4-2 Wiring
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
4
System Design
R88D-KT20H
Main Circuit Connector Specifications (CNA)
Motor Connector Specifications (CNB)
External Regeneration Resistor Connector Specifications (CNC)
Symbol
Name Function
L1 Main circuit power supply
input
R88D-KTxH (2 kW) :
3-phase: 200 to 230 VAC (170 to 253 V) 50/60 Hz
L2
L3
L1C Control circuit power
supply input
R88D-KTxH : Single-phase 200 to 230 VAC (170 to 253 V) 50/60
Hz
L2C
Symbol
Name Function
U Motor connection
terminals
Red These are the output terminals to the Servomotor.
Be sure to wire them correctly.
VWhite
WBlue
Green/
Yellow
Frame ground This is the ground terminal. Ground to 100 Ω or less.
Symbol
Name Function
B1 External Regeneration
Resistor connection
terminals
Normally B2 and B3 are short-circuited.
If there is high regenerative energy, remove the short-circuit bar
between B2 and B3 and connect an External Regeneration
Resistor between B1 and B2.
When using N terminal, make sure not to exceed the fuse's rated
voltage (360 VDC, 60 A).
B2
B3
N