8-57
8-6 Extended Parameters
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
8
Parameters Details
Select the data to be displayed on the 7-segment LED on the front panel after the power supply
is turned ON.
For information on the display, refer to "9-4 Setting the Mode" (P.9-8).
Set the axis number for communication.
Set the maximum command pulse input.
Err27.0 occurs if frecuency exceeds this range
2 Position command speed
3 Speed control command
4 Torque command
5 Total encoder pulses
6 Total command pulses
8 Total external scale feedback pulses
9 CONTROL mode
10 I/O signal status
11 Analog input value
12 Error factor, history
13 Warning number
14 Regeneration resistance load ratio
15 Overload load ratio
16 Inertia ratio
17 Reason for no rotation
18 Display of the number of I/O signal changes
20 Absolute encoder data
21 Absolute external scale position
22 Monitor for the number of encoder communications errors
23 Display of axis numbers for communication
24 Position error (encoder unit)
25 External scale error (external scale unit)
26 Hybrid error
27 P-N voltage
28 Soft version
29 Driver serial number
30 Motor serial number
31 Accumulative operation time
32 Automatic motor recognition function
33 Driver temperature
35 Safety status monitor
Set value
Explanation
Pn531
Axis Number
Setting
range
0 to 127 Unit
Default
setting
1
Power OFF
and ON
Yes
All
Pn532
Command Pulse Input Maximum Setting
Setting
range
250 to 4,000 Unit kpps
Default
setting
4000
Power OFF
and ON
Yes
Position
Full closing