12-23
12-2 Parameter List
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
12
Appendix
409
Input Signal
Selection 10
Set the input signal 10 function and logic. 3720
0 to
00FFFFFFh
Yes
410
Output Signal
Selection 1
Set the output signal 1 function allocation. 197379
0 to
00FFFFFFh
Yes
411
Output Signal
Selection 2
Set the output signal 2 function allocation. 131586
0 to
00FFFFFFh
Yes
412 Not used Do not change the set value. - −−
413
Output Signal
Selection 4
Set the output signal 4 function allocation. 65793
0 to
00FFFFFFh
Yes
416
Analog Monitor
1 Selection
Select the type for analog monitor 1.
0 0 to 21
0 Motor speed
1 Position command speed
2 Internal position command speed
3 Speed Control Command
4 Torque command
5 Command position error
6 Encoder Position Error
7 Full closing Error
8 Hybrid Error
9 P-N voltage
10 Regeneration load ratio
11 Overload load ratio
12 Forward direction torque limit
13 Reverse direction torque limit
14 Speed limit value
15 Inertia Ratio
16 Analog input 1
17 Analog input 2
18 Analog input 3
19 Reserved
20 Driver temperature
21 Encoder 1-rotation data
417
Analog Monitor
1 Scale Setting
Set the output gain for analog monitor 1. 0
0 to
214,748,364
418
Analog Monitor
2 Selection
Select the type for analog monitor 2.
The set values for this parameter are the
same as Analog Monitor 1 Type (Pn416).
4 0 to 21
419
Analog Monitor
2 Scale Setting
Select the output gain for analog monitor 2. 0
0 to
214,748,364
Pn number
Parameter
name
Explanation
Default
setting
Unit
Setting
range
Power