12-24
12-2 Parameter List
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
12
Appendix
421
Analog Monitor
Output Setting
Select the analog monitor output voltage method.
0 0 to 2
0
Output range: -10 to 10 V
Data output: Positive, negative
1
Output range: 0 to 10 V
Data output: Positive, negative
2
Output range: 0 to 10 V
Data output: Positive, negative
422
Analog Input 1 Offset
Set the analog input 1 offset. 0
0.359 mV
-5,578 to
5,578
423
Analog Input 1 Filter
Time Constant
Set the analog input 1 filter. 0
0.01
ms
0 to
6,400
424
Excessive
Analog Input 1
Set the voltage after offset for the excess
level of analog input 1 input voltage.
0 0.1 V 0 to 100
425
Analog Input 2 Offset
Set the analog input 2 offset. 0
5.86 mV
-342 to 342
426
Analog Input 2 Filter
Time Constant
Set the analog input 2 filter. 0
0.01
ms
0 to
6,400
427
Excessive
Analog Input 2
Set the voltage after offset for the excess
level of analog input 2 input voltage.
0 0.1 V 0 to 100
428
Analog Input 3 Offset
Set the analog input 3 offset. 0
5.86 mV
-342 to 342
429
Analog Input 3 Filter
Time Constant
Set the analog input 3 filter. 0
0.01
ms
0 to
6,400
430
Excessive
Analog Input 3
Set the voltage after offset for the excess
level of analog input 3 input voltage.
0 0.1 V 0 to 100
431
Positioning
Completion Range 1
Set the allowed number of pulses for the
positioning completion range.
10
Command
unit
0 to
262,144
432
Positioning
Completion
Condition
Selection
Set the judgment conditions for positioning completion output.
0 0 to 3
0
Positioning completion output turns ON
when the position error is within the
Positioning Completion Range 1 (Pn431).
1
Positioning completion output turns ON when the
position error is within the Positioning Completion
Range 1 (Pn431) and there is no position command.
2
Positioning completion output turns ON when the
zero speed detection signal is ON, the position
error is within the Positioning Completion Range
1 (Pn431), and there is no position command.
3
Positioning completion output turns ON when
the position error is within the Positioning
Completion Range 1 (Pn431) and there is no
position command. The ON status will then be
held until the next position command is received.
433
Positioning Completion
Hold Time
Set the positioning completion hold time. 0 1 ms
0 to
30,000
434
Zero Speed
Detection
Set the detection threshold for zero speed
(ZSP).
50 r/min
10 to
20,000
435
Speed
Conformity
Detection Range
Set the detection threshold for speed conformity
output (V-COIN) with the difference between
the speed command and the actual speed.
50 r/min
10 to
20,000
Pn number
Parameter
name
Explanation
Default
setting
Unit
Setting
range
Power
supply
OFF to
ON
Setting

Table of Contents