7 - 27
7 Parameter Details
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
7-4 Analog Control Parameters
7
Do not set.
Do not set.
Pn302 Reserved
Setting
range
500 Unit Default
setting
500
Cycle the
power supply
Pn303 Reserved
Setting
range
1 Unit Default
setting
1
Cycle the
power supply
Pn304
No. 1 Internally Set Speed
Setting
range
–20,000 to 20,000 Unit r/min Default
setting
0
Cycle the
power supply
Pn305
No. 2 Internally Set Speed
Setting
range
–20,000 to 20,000 Unit r/min Default
setting
0
Cycle the
power supply
Pn306
No. 3 Internally Set Speed
Setting
range
–20,000 to 20,000 Unit r/min Default
setting
0
Cycle the
power supply
Pn307
No. 4 Internally Set Speed
Setting
range
–20,000 to 20,000 Unit r/min Default
setting
0
Cycle the
power supply
Pn308
No. 5 Internally Set Speed
Setting
range
–20,000 to 20,000 Unit r/min Default
setting
0
Cycle the
power supply
Pn309
No. 6 Internally Set Speed
Setting
range
–20,000 to 20,000 Unit r/min Default
setting
0
Cycle the
power supply
Pn310
No. 7 Internally Set Speed
Setting
range
–20,000 to 20,000 Unit r/min Default
setting
0
Cycle the
power supply
Speed
Speed
Speed
Speed
Speed
Speed
Speed

Table of Contents

Other manuals for Omron G5 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron G5 Series and is the answer not in the manual?

Omron G5 Series Specifications

General IconGeneral
FeedbackIncremental Encoder, Absolute Encoder
CommunicationEtherCAT
Safety FunctionSTO (Safe Torque Off)
Protection FunctionsOvervoltage, Undervoltage, Overcurrent
Vibration Resistance4.9 m/s² (10 to 55 Hz)

Related product manuals