5-30 HS-360X Handheld DPM Scanner User Manual
User Preferences
Hands-Free Decode Session Timeout
Parameter # 400
This parameter is the Hands-free compliment to the
Decode Session Timeout
. It configures
the minimum and maximum decode processing time during a Hands-free scan attempt. It
only applies to the Hands-free trigger mode.
The minimum decode processing time is defined as the time in which the scanner stops
decoding when an object is removed or left stationary in the imaging field of view.
The maximum decode processing time is defined as the time in which the scanner stops
decoding when an object is left in or is moving in the field of view.
Both the maximum and minimum times are configured using a single setting. The relationship
of this setting is as follows:
For example, a setting value of 100 results in the scanner turning off approximately 1 second
after an object is removed from the field of view or 10 seconds while an object is in the
field of view moving.
The default value of the setting is 15 which results in a Minimum time of 250 msec and
Maximum time of 2.5 seconds.
Adjust this setting based on your requirements. For example, when doing prioritization,
this parameter should be set to a value where the maximum time is above the PDF prioritization
timeout.
Setting Value Minimum Time Maximum Time
X < 25 250 msec 2.5 Seconds
X >= 25 X * 10 msec X * 100 msec
Hands-free Decode Session Timeout