HS-360X Handheld DPM Scanner User Manual 5-29
User Preferences and Miscellaneous Options
Decode Session Timeout
Parameter # 136
This parameter sets the maximum time decode processing continues during a scan
attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds. The default
timeout is 9.9 seconds.
To set a Decode Session Timeout, scan the programming symbol below. Next, scan two
numeric programming symbol from Appendix H Numeric Keyboard that correspond
to the desired on time. Enter a leading zero for single digit numbers. For example, to set a
Decode Session Timeout of 0.5 seconds, scan the programming symbol below, then scan
the
0
and
5
programming symbols.
Decode Session Timeout