7-20 HS-360X Handheld DPM Scanner User Manual
Optional USB Parameters
Optional USB Parameters
If you configure the scanner and find the settings were not saved, or changed, when the system
is restarted scan the programming symbols that follow to override USB interface defaults.
Scan a programming symbol below after setting defaults and before configuring the scanner.
Ignore Beep
The host can send a beep request to the scanner. When this parameter is enabled, the
request is not sent to the attached scanner. All directives are still acknowledged to the
USB host as if it were processed.
Disable Ignore Beep
* Enable Ignore Beep