7-6 HS-360X Handheld DPM Scanner User Manual
USB Host Parameters
USB Host Parameters
USB Device Type
Select the desired USB device type.
1. When changing USB device types, the scanner automatically restarts. The scanner
issues a power-up beep sequence.
2.
Before selecting
USB CDC Host
, install the Omron Microscan USB CDC Driver on the host
to ensure the scanner does not stall during power up (due to a failure to enumerate USB).
To recover a stalled scanner:
• Install the CDC Driver.
or
• For the HS-360X Wireless Scanner, unplug the USB cable and add power. Connect
the scanner via Bluetooth and scan HID Keyboard or another host.
• For the HS-360X Wired Scanner, unplug the USB cable, while holding the trigger,
re-plug the USB cable. After 5 seconds, the scanner temporarily comes up in HID
Keyboard, scan another host.
* HID Keyboard Emulation
USB CDC Host
(Note 1)