HS-360X Handheld DPM Scanner User Manual 5-47
User Preferences and Miscellaneous Options
Unsolicited Heartbeat Interval
Parameter # 1118
The imager supports sending Unsolicited Heartbeat Messages to assist in diagnostics.
To enable this feature and set the desired unsolicited heartbeat interval, scan one of the
time interval programming symbols below, or scan Set Another Interval followed by four
numeric programming symbols from Appendix H Numeric Keyboard (scan sequential
numbers that correspond to the desired number of seconds). The range is 0 - 9999.
Scan Disable Unsolicited Heartbeat Interval to turn off the feature.
The heartbeat event is sent as decode data (with no decode beep) in the form of:
MOTEVTHB:nnn
where nnn is a three-digit sequence number starting at 001 and wrapping after 100.