4-20 MicroHAWK Engine Integration Guide
USB HID/Keyboard
USB HID/Keyboard
Omron Microscan Report Enabled
Keyboard Report Enabled
Keyboard Language
Definition: These parameters cause the reader to reboot after a <Z> or <A> command.
The data packet is structured for input and output as follows:
Byte 1 = Report Type (Always 1)
Byte 2 = Data Length (Hex Format)
Byte 3 – 64 = Data to Command Processor
Serial Cmd:
<K149,Omron Microscan Report Enabled,Keyboard Report Enabled,Keyboard
Language,USB VCOM Status,UART Status>
Serial Cmd:
<K149,Omron Microscan Report Enabled,Keyboard Report Enabled,Keyboard
Language,USB VCOM Status,UART Status>
Default: 0 = Disabled
Options: 0 = Disabled
1 = Enabled
Serial Cmd:
<K149,Omron Microscan Report Enabled,Keyboard Report Enabled,Keyboard
Language,USB VCOM Status,UART Status>
Default: 0 = Disabled
Options: 0 = Disabled
1 = Enabled
Definition: Used by the reader to help identify what keyboard layout to use when the
keyboard drive is outputting data. If the unit does not have the keyboard
layout assigned to this parameter, than it will default to the en-US keyboard
layout. On the next page is the list of acceptable languages with predefined
keyboard layouts. If they are pre-loaded into the reader’s firmware they are
shown in bold. All other languages will need to be manually loaded as a
keyboard.def file or added to the reader’s firmware.
Serial Cmd: <K149,Omron Mic
roscan Report Enabled,Keyboard Report Enabled,Keyboard
Language,USB VCOM Status,UART Status>
Default: en-US
Options: ASCII string, up to 25 characters