8-34 MicroHAWK Engine Integration Guide
Service Message
Service Message
When Service Message is enabled, a message of up to 10 ASCII characters is sent
whenever the system detects that the service timer’s limit has been reached. The service
timer is reset at power-on, meaning that the service timers limit is the amount of time
since last reset. Service timer increments can be set in seconds or minutes.
Service Message
Threshold
Resolution
Serial Cmd: <K409,status,service message,threshold,resolution>
Default: 0
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K409,status,service message,threshold,resolution>
Default: SERVICE
Options: An ASCII string between 1 and 10 characters.
Serial Cmd: <K409,status,service message,threshold,resolution>
Default: 300 (5 minutes)
Options: 1 to 65535
Serial Cmd: <K409,status,service message,threshold,resolution>
Default: Seconds
Options: 0 = Seconds 1 = Minutes