MicroHAWK Engine Integration Guide 4-3
Communications
Communications Serial Commands
Host Port Connections <K100,baud rate,parity,stop bits,data bits>
Ethernet
<
K126,
status,IP address,subnet,gateway,IP address mode>
Ethernet TCP Ports <K127,TCP Port 1,TCP Port 2>
Search and Configure Mode <K128,status,timed window>
EtherNet/IP <K129,status>
Host Protocol <K140,protocol,address>
Preamble <K141,status,preamble characters>
Postamble <K142,status,postamble characters>
Response Timeout <K143,response timeout>
LRC Status <K145,status>
ACK/NAK Options <K147,RES,REQ,STX,ETX,ACK,NAK>
Polling Mode Options <K148,RES,REQ,STX,ETX,ACK,NAK>
USB HID/Keyboard
<K149,Omron Microscan Report Enabled,Keyboard
Report Enabled,Keyboard Language,USB VCOM
Status, UART Status>
EtherNet/IP Byte Swapping Enabled
<K163,status>
USB Mass Storage Driver <K900,status>