MicroHAWK Engine Integration Guide 8-39
I/O Parameters
Image Output Example
The following example assumes that the reader is set to output on No-Read, and that it is
in a rapid capture mode of 3 captures.
Number of Symbols: 1
Frame # 1: No-Read
Frame # 2: No-Read
Frame # 3: No-Read
Read Cycle Result: No-Read
Output Frame: Frame # 1
Number of Symbols: 1
Frame # 1: No-Read
Frame # 2: No-Read
Frame # 3: Good Read
Read Cycle Result: Good Read
Output Frame: None
Number of Symbols: 2
Frame # 1: No-Read
Frame # 2: No-Read
Frame # 3: Good Read, Symbol # 1
Read Cycle Result: No-Read
Output Frame: Frame # 1