MicroHAWK Engine Integration Guide 8-43
I/O Parameters
No Read
Outputs the first No Read image in the read cycle. The image file will immediately follow
the symbol data.
Note: If two symbols are present in the same image capture and one of them is successfully
decoded, no image will be output.
No Read and Good Read
Outputs the first No Read or Good Read image in the read cycle.
Mismatch
Outputs the image of the first mismatch condition.
Image Format
Lossless
A “lossless” image is one that is in a high resolution format, and that will not lose resolution
even when manipulated and saved multiple times. When Lossless is enabled, the JPEG
Quality setting has no effect.
Compressed
Outputs the image in JPEG format. Image quality is determined by the JPEG Quality
setting.
Image Quality
Definition: Selects the format of the image output file.
Serial Cmd:
<
K757,
status,transfer
port,image mode,
image format
,image quality,object
info
enable
,grade enable
>
Default: Compressed
Options: 0 = Lossless 1 = Compressed
Definition: Sets the amount of image compression. A value of 1 represents the highest
compression and lowest image quality, and 100 represents the lowest
compression and highest image quality.
Serial Cmd:
<
K757,
status,transfer port,image mode,image format,
image quality
,object
info enable
,grade enable
>
Default: 90
Options: 1 to 100 (percent)