9-14 MicroHAWK Engine Integration Guide
Omron Microscan Symbol Quality Output
Decode Time
Pixels Per Element (Data Matrix Only)
Error Correction Level (Data Matrix Only)
Matrix Size (Data Matrix Only)
Definition: The time in milliseconds required to decode a symbol.
When enabled, the decode time is appended to the symbol data.
Serial Cmd: <K710,percent cell damage,total read time,capture time,locate
time,decode time,pixels per element,ECC level,matrix size,quiet
zone,symbol angle>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: The number of pixels for each element, either dark or light for both x and
y directions.
When enabled, the pixels per element value is appended to the symbol
data.
Serial Cmd: <K710,percent cell damage,total read time,capture time,locate
time,decode time,pixels per element,ECC level,matrix size,quiet
zone,symbol angle>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: Outputs the Data Matrix ECC level.
When enabled, the ECC level is appended to the symbol data.
Serial Cmd: <K710,percent cell damage,total read time,capture time,locate
time,decode time,pixels per element,ECC level,matrix size,quiet
zone,symbol angle>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: Defines the symbol matrix size, in number of pixels in both the x and y
axis.
When enabled, the matrix size value is appended to the symbol data.
Serial Cmd: <K710,percent cell damage,total read time,capture time,locate
time,decode time,pixels per element,ECC level,matrix size,quiet
zone,symbol angle>
Default: Disabled
Options: 0 = Disabled 1 = Enabled