5-20
H Setting Frequency References 1 through 16 and the Inching
Frequency Command (n024 through n031, n120 through
n127)
Frequency references 1 through 16 and an inching frequency command can be set
together in the Inverter (using registers n024 through n31, n120 through n127).
D Setting Frequency References 1 through 16 (n024 through n31, n120
through n127)
n024 Frequency Reference 1 Register 0118
Hex
Changes during
operation
Yes
Setting
range
0.00 to max. frequency Unit of
setting
0.01 Hz
(see
note 1)
Default setting 6.0
n025 Frequency Reference 2 Register 0119
Hex
Changes during
operation
Yes
Setting
range
0.00 to max. frequency Unit of
setting
0.01 Hz
(see
note 1)
Default setting 0.00
n026 Frequency Reference 3 Register 011A
Hex
Changes during
operation
Yes
Setting
range
0.00 to max. frequency Unit of
setting
0.01 Hz
(see
note 1)
Default setting 0.00
n027 Frequency Reference 4 Register 011B
Hex
Changes during
operation
Yes
Setting
range
0.00 to max. frequency Unit of
setting
0.01 Hz
(see
note 1)
Default setting 0.00
n028 Frequency Reference 5 Register 011C
Hex
Changes during
operation
Yes
Setting
range
0.00 to max. frequency Unit of
setting
0.01 Hz
(see
note 1)
Default setting 0.00
n029 Frequency Reference 6 Register 011D
Hex
Changes during
operation
Yes
Setting
range
0.00 to max. frequency Unit of
setting
0.01 Hz
(see
note 1)
Default setting 0.00
Basic Operation Chapter 5