Transportation Precautions
Caution Donotholdbyfrontcoverorpanel,instead,holdbytheradiationfin(heatsink)while
transporting the product. Doing so may result in injury.
Caution Donotpullonthecables.Doingsomayresultindamagetotheproductormalfunc-
tion.
Caution Use the eye-bolts only for transporting the Inverter. Using them for transporting the
machinery may result in injury or malfunction.
Installation Precautions
Caution Be sure to install the product in the correct direction and provide specified clear-
ances between the Inverter and control panel or with other devices. Not doing so
may result in fire or malfunction.
Caution Donotallowforeignobjectstoenterinsidetheproduct.Doingsomayresultinfireor
malfunction.
Caution Do not apply any strong impact. Doing so may result in damage to the product or
malfunction.
Caution Provide an appropriate stopping device on the machine side to secure safety. (A
holdingbrakeisnotastoppingdeviceforsecuringsafety.)Notdoingsomayresultin
injury.
Caution Provideanexternalemergencystoppingdevicethatallowsaninstantaneousstopof
operation and power interruption. Not doing so may result in injury.
Wiring Precautions
WARNING Wiring must be performed only after confirming that the power supply has been
turned OFF. Not doing so may result in electrical shock.
WARNING Wiring must be performed by authorized personnel. Not doing so may result in
electrical shock or fire.
WARNING Be sure to confirmoperation only after wiring theemergency stop circuit. Not doing
so may result in injury.
WARNING Always connect the ground terminals to a ground of 100 W or less for the 200-VAC
class,or10 W orlessfor the400-VACclass. Notconnectingtoa propergroundmay
result in electrical shock.

Table of Contents

Other manuals for Omron SYSDRIVE 3G3MV

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3MV and is the answer not in the manual?

Omron SYSDRIVE 3G3MV Specifications

General IconGeneral
CategoryInverter
Input Frequency50/60 Hz
Output Frequency0.1-400 Hz
Cooling MethodForced Air Cooling
Communication InterfaceRS-485
ModelOmron SYSDRIVE 3G3MV
ProtectionOvercurrent, Overvoltage, Overheat
Ambient Temperature-10 to 50°C
Overload Capacity150% for 60 seconds
Storage Temperature-20 to 65°C
Humidity20 to 90% RH (non-condensing)
AltitudeUp to 1000m above sea level
Input Voltage200-230V, 380-460V