Caution Install external breakers and take other safety measures against short-circuiting in
external wiring. Not doing so may result in fire.
Caution ConfirmthattheratedinputvoltageoftheInverteristhesameastheACpowersup-
ply voltage. An incorrect power supply may result in fire, injury, or malfunction.
Caution IfyouuseaBrakingResistororaBrakingResistorUnit,connectthemasspecifiedin
the manual. Not doing so may result in fire.
Caution Besuretowirecorrectlyandsecurely.Notdoingsomayresultininjuryordamageto
the product.
Caution Besureto firmlytightenthescrews ontheterminalblock.Notdoingsomay result in
fire, injury, or damage to the product.
Caution DonotconnectanACpowertotheU,V,orWoutput.Doingsomayresultindamage
to the product or malfunction.
Operation and Adjustment Precautions
WARNING TurnONtheinputpowersupplyonlyaftermountingthefrontcover,terminalcovers,
bottom cover, Operator, and optional items. Not doing so may result in electrical
shock.
WARNING Do not remove the front cover, terminal covers,bottom cover, Operator, or optional
items while the powerisbeingsupplied. Not doing so may resultinelectricalshock.
WARNING Do not operate the Operator or switches with wet hands. Doing so may result in
electrical shock.
WARNING Do not touch the inside of the Inverter. Doing so may result in electrical shock.
WARNING Do not come close to the machine when using the error retry function because the
machinemayabruptlystartwhenstoppedbyanalarm.Doingsomayresultininjury.
WARNING Do not come close to the machine immediately after resetting momentary power
interruption to avoid anunexpected restart (if operation is set tobe continued in the
processingselectionfunctionaftermomentarypowerinterruptionisreset).Doingso
may result in injury.
WARNING Provideaseparate emergencystopswitchbecausetheSTOPKeyontheOperator
isvalidonlywhenfunctionsettingsareperformed.Notdoingsomayresultininjury.

Table of Contents

Other manuals for Omron SYSDRIVE 3G3MV

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3MV and is the answer not in the manual?

Omron SYSDRIVE 3G3MV Specifications

General IconGeneral
CategoryInverter
Input Frequency50/60 Hz
Output Frequency0.1-400 Hz
Cooling MethodForced Air Cooling
Communication InterfaceRS-485
ModelOmron SYSDRIVE 3G3MV
ProtectionOvercurrent, Overvoltage, Overheat
Ambient Temperature-10 to 50°C
Overload Capacity150% for 60 seconds
Storage Temperature-20 to 65°C
Humidity20 to 90% RH (non-condensing)
AltitudeUp to 1000m above sea level
Input Voltage200-230V, 380-460V