WARNING Be sure confirm that the RUN signal is turned OFF before turning ON the power
supply, resetting the alarm, or switching the LOCAL/REMOTE selector. Doing so
while the RUN signal is turned ON may result in injury.
Caution Be sure to confirm permissible ranges of motors and machines before operation
because the Inverter speed can be easily changed from low to high. Not doing so
may result in damage to the product.
Caution Provideaseparateholdingbrakewhen necessary.Notdoingsomayresultininjury.
Caution Donotperformasignalcheckduringoperation.Doingsomayresultininjuryordam-
age to the product.
Caution Do not carelessly change settings. Doing so may result in injury or damage to the
product.
Maintenance and Inspection Precautions
WARNING Do not touch the Inverter terminals while the power is being supplied.
WARNING Maintenance or inspection must be performed only after turning OFF the power
supply, confirming that the CHARGE indicator (or status indicators) is turned OFF,
andafterwaitingforthetimespecifiedonthe front cover. Notdoing somay result in
electrical shock.
WARNING Maintenance, inspection, or parts replacement must be performed by authorized
personnel. Not doing so may result in electrical shock or injury.
WARNING Do not attempt to take the Unit apart or repair. Doing either of these may result in
electrical shock or injury.
Caution Carefully handle the Inverter because it uses semiconductor elements. Careless
handling may result in malfunction.
Caution Do not change wiring, disconnect connectors or Operator, or replace fans while
power is being supplied. Doing so may result in injury or malfunction.

Table of Contents

Other manuals for Omron SYSDRIVE 3G3MV

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3MV and is the answer not in the manual?

Omron SYSDRIVE 3G3MV Specifications

General IconGeneral
CategoryInverter
Input Frequency50/60 Hz
Output Frequency0.1-400 Hz
Cooling MethodForced Air Cooling
Communication InterfaceRS-485
ModelOmron SYSDRIVE 3G3MV
ProtectionOvercurrent, Overvoltage, Overheat
Ambient Temperature-10 to 50°C
Overload Capacity150% for 60 seconds
Storage Temperature-20 to 65°C
Humidity20 to 90% RH (non-condensing)
AltitudeUp to 1000m above sea level
Input Voltage200-230V, 380-460V