Name Function
Data display Displays relevant data items, such as frequency
reference, output frequency, and parameter set
values.
FREQUENCY
adjuster
Sets the frequency reference within a range
between 0 Hz and the maximum output
frequency.
FREF indicator The frequency reference can be monitored or set
while this indicator is lit.
FOUT indicator The output frequency of the Inverter can be
monitored while this indicator is lit.
IOUT indicator The output current of the Inverter can be
monitored while this indicator is lit.
MNTR indicator The values set in U01 through U18 are
monitored while this indicator is lit. Depending on
the inverter capacity, the quantity of the Uxx will
be different.
F/R indicator The direction of rotation can be selected while
this indicator is lit when operating the Inverter
with the RUN Key.
LO/RE indicator The operation of the Inverter through the Digital
Operator or according to the set parameters is
selectable while this indicator is lit.
Note This status of this indicator can be only
monitored while the Inverter is inoperation.
Any RUN command input is ignored while
this indicator is lit.
Overview Chapter 1