1-7
Appearance FunctionName
PRGM indicator The parameters in n001 through n179 can be set
or monitored while this indicator is lit.
Note While the Inverter is in operation, the
parameterscanbe onlymonitored and only
some parameters can be changed. Any
RUN command input is ignored while this
indicator is lit. Unless n001 is 5.
Mode Key Switches the simplified-LED (setting and
monitor) item indicators in sequence.
Parameter being set will be canceled if this key is
pressed before entering the setting.
Increment Key Increases multi-function monitor numbers,
parameter numbers, and parameter set values.
Decrement Key Decreases multi-function monitor numbers,
parameter numbers, and parameter set values.
Enter Key Enters multi-function monitor numbers,
parameter numbers, and internal data values
after they are set or changed.
RUN Key Starts the Inverter running when the 3G3MV is in
operation with the Digital Operator.
STOP/RESET Key Stops the Inverter unless parameter n007 is set
to disable the STOP Key. Functions as a Reset
Key when an inverter error occurs (see note).
Note Forsafetyreasons,theresetwillnotworkwhileaRUNcommand(forwardorreverse)isineffect.
Wait until the RUN command is OFF before resetting the Inverter.
Overview Chapter 1